📝 fgvillegas's Posts

fgvillegas

📍 Philippines
Member
Posts
107
Vehicles
0

Cold Air Intake Pipe Diameter - 6G Celicas Forums

EnthusiastJoined Mar 22, '10From PhilippinesCurrentlyOfflineReputation:0(0%)
6th Generation Celica › Engine/Transmission/Maintenance
Hi Guys,
i am just wondering what would be the best cold air intake pipe diameter for a 3rd gen 3sge with a throttle body of 65mm (2 and 5/8").
my current setup uses 3" diameter which i think is good ...
Topic ID: 73960 • Post ID: 9504416

PIVOT Raizen Voltage Stabilizer - 6G Celicas Forums

EnthusiastJoined Mar 22, '10From PhilippinesCurrentlyOfflineReputation:0(0%)
6th Generation Celica › Engine/Transmission/Maintenance
I have one installed on my car but I cannot quantify the gains since I have it already when I have my car dynoed. But from what I know, your gain would be around 0 to 2 whp based on what I've read.
Topic ID: 73872 • Post ID: 9503744

mystery noise, help :) - 6G Celicas Forums

EnthusiastJoined Mar 22, '10From PhilippinesCurrentlyOfflineReputation:0(0%)
6th Generation Celica › Engine/Transmission/Maintenance
Good to know that the mystery sound is now gone.
Topic ID: 73730 • Post ID: 9501892

mystery noise, help :) - 6G Celicas Forums

EnthusiastJoined Mar 22, '10From PhilippinesCurrentlyOfflineReputation:0(0%)
6th Generation Celica › Engine/Transmission/Maintenance
One thing you can try before openning your tranny is to spray some wd40 kind of stuff in the area beside the clutch fork. You can open up the rubber portion there before spraying it. My friend encount...
Topic ID: 73730 • Post ID: 9501886

With or Without O2 Sensor? - 6G Celicas Forums

EnthusiastJoined Mar 22, '10From PhilippinesCurrentlyOfflineReputation:0(0%)
6th Generation Celica › Engine/Transmission/Maintenance
Hi,
Just recently, I learned the my O2 sensor is not functioning properly so I took out the connecting plug from the sensor to make the car run better than a damaged O2 sensor. From what I understand...
Topic ID: 73664 • Post ID: 9501341

Engine cranks but wont start - 6G Celicas Forums

EnthusiastJoined Mar 22, '10From PhilippinesCurrentlyOfflineReputation:0(0%)
6th Generation Celica › Engine/Transmission/Maintenance
Is the timing belt loose enough to slip when the pulley turns? If so, this may damage the engine if you try to continue starting the engine. I am no expert but I guess that while you were running at 4...
Topic ID: 73662 • Post ID: 9501336

3rd Gen 3S-GE Standard Fuel Pressure - 6G Celicas Forums

EnthusiastJoined Mar 22, '10From PhilippinesCurrentlyOfflineReputation:0(0%)
6th Generation Celica › Engine/Transmission/Maintenance
QUOTE (Rusty @ Apr 24, 2010 - 2:45 AM)
fuel pressure at idle should be between 38 - 44 psi or 2.6 - 3.0 bar
Thanks Rusty!
As always, you're always here to help!
Topic ID: 73487 • Post ID: 9499654

3rd Gen 3S-GE Standard Fuel Pressure - 6G Celicas Forums

EnthusiastJoined Mar 22, '10From PhilippinesCurrentlyOfflineReputation:0(0%)
6th Generation Celica › Engine/Transmission/Maintenance
Hi Guys,
It's me again and another question.
What is the standard fuel pressure for a 3rd Gen 3S-GE? Is it 2.5 bar (35 psi) or 2.1 bar (30 psi)?
If it is not even one of the above, please let me know....
Topic ID: 73487 • Post ID: 9499652

Fuel Presure Reg (3sge = 3sfe) - 6G Celicas Forums

EnthusiastJoined Mar 22, '10From PhilippinesCurrentlyOfflineReputation:0(0%)
6th Generation Celica › Engine/Transmission/Maintenance
Thanks Rusty
Topic ID: 73407 • Post ID: 9498849

Fuel Presure Reg (3sge = 3sfe) - 6G Celicas Forums

EnthusiastJoined Mar 22, '10From PhilippinesCurrentlyOfflineReputation:0(0%)
6th Generation Celica › Engine/Transmission/Maintenance
Just to add, is the 3sge and 3sgte fuel reg interchangeable?
Thanks
Topic ID: 73407 • Post ID: 9498847

Fuel Presure Reg (3sge = 3sfe) - 6G Celicas Forums

EnthusiastJoined Mar 22, '10From PhilippinesCurrentlyOfflineReputation:0(0%)
6th Generation Celica › Engine/Transmission/Maintenance
Hi guys,
Is the stock fuel pressure regulator of a 3rd gen 3sge the same as 3sfe?
Thanks,
Topic ID: 73407 • Post ID: 9498846

Engine Problem, Please Help! - Problem Solved - 6G Celicas Forums

EnthusiastJoined Mar 22, '10From PhilippinesCurrentlyOfflineReputation:0(0%)
6th Generation Celica › Engine/Transmission/Maintenance
Hi Guys,
I finally figured what the problem is. It's the O2 sensor.
I first reset to ECU before disconnecting the O2 sensor socket then I zeroed out the air correction of my SAFC2. When I started the ...
Topic ID: 73268 • Post ID: 9486996

Engine Problem, Please Help! - Problem Solved - 6G Celicas Forums

EnthusiastJoined Mar 22, '10From PhilippinesCurrentlyOfflineReputation:0(0%)
6th Generation Celica › Engine/Transmission/Maintenance
I was thinking if the problem could be the MAP sensor or the O2 sensor.
Will the computer use some default settings if I disconnect the O2 sensor? If this is the case, then if the behavior of the car ...
Topic ID: 73268 • Post ID: 9486995

Engine Problem, Please Help! - Problem Solved - 6G Celicas Forums

EnthusiastJoined Mar 22, '10From PhilippinesCurrentlyOfflineReputation:0(0%)
6th Generation Celica › Engine/Transmission/Maintenance
Just an update on this.
I have done the following:
- clean throttle body
- replaced fuel filter
- cleaned fuel pump filter
- replaced fuel pressure regulator
- cleaned some other vacuum related hoses ...
Topic ID: 73268 • Post ID: 9486994

Engine Problem, Please Help! - Problem Solved - 6G Celicas Forums

EnthusiastJoined Mar 22, '10From PhilippinesCurrentlyOfflineReputation:0(0%)
6th Generation Celica › Engine/Transmission/Maintenance
QUOTE (808celica @ Apr 13, 2010 - 4:07 AM)
idle control valve
every 100k miles
Thanks again.
What should I do with the idle control valve?
Topic ID: 73268 • Post ID: 9486993

Engine Problem, Please Help! - Problem Solved - 6G Celicas Forums

EnthusiastJoined Mar 22, '10From PhilippinesCurrentlyOfflineReputation:0(0%)
6th Generation Celica › Engine/Transmission/Maintenance
QUOTE (808celica @ Apr 12, 2010 - 11:00 PM)
Auto or manual??
Clean your throttle body, use injector cleaner, change the fuel filter, and check your cap and rotors.
Thanks for your immediate reply.
It'...
Topic ID: 73268 • Post ID: 9486991

Engine Problem, Please Help! - Problem Solved - 6G Celicas Forums

EnthusiastJoined Mar 22, '10From PhilippinesCurrentlyOfflineReputation:0(0%)
6th Generation Celica › Engine/Transmission/Maintenance
Hi Guys,
I have a problem when I have just started the engine specially when the car was not used for an hour or so. And the problem is sure to happen on cold start.
Everything seems normal when I sta...
Topic ID: 73268 • Post ID: 9486989

MSD 5 - 6G Celicas Forums

EnthusiastJoined Mar 22, '10From PhilippinesCurrentlyOfflineReputation:0(0%)
6th Generation Celica › Engine/Transmission/Maintenance
QUOTE (millow @ Apr 15, 2010 - 4:02 AM)
fgvillegas, what tach adaptor did you use for your MSD 6A, did you use msd pn 8910-EIS, nothing esle.
yup!
Topic ID: 73266 • Post ID: 9486983

MSD 5 - 6G Celicas Forums

EnthusiastJoined Mar 22, '10From PhilippinesCurrentlyOfflineReputation:0(0%)
6th Generation Celica › Engine/Transmission/Maintenance
QUOTE (kavy @ Apr 12, 2010 - 8:38 PM)
ok,so its been two days since my cousin has been trying to hook up a multiple spark discharge 5 unit in my 3sge.we tried running it with all of the wiring diagram...
Topic ID: 73266 • Post ID: 9486981

Shifting problems - 6G Celicas Forums

EnthusiastJoined Mar 22, '10From PhilippinesCurrentlyOfflineReputation:0(0%)
6th Generation Celica › Engine/Transmission/Maintenance
That happened once to me and the pressure plate was the culprit.
The thing is, I have done the following one by one before it was finally detected:
- Replaced clutch master and clutch fluid. Secondary...
Topic ID: 72944 • Post ID: 9481696
← Previous 3 4 5 6 Next →
Showing page 5 of 6 (107 total posts)